Solar plant: site data
Solar power plant in Zamistia, Berdianskyi Raion, Zaporizhzhia Oblast
Zamistia: 1,221 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 0.8% above the oblast median (1,212). #62 of 116 in the rayon, #302 of 972 in the oblast.
Berdyansk, the rayon centre, is 66 km away. 88 m above sea level. 47 km away: Pryazovske, the nearest bigger centre, 1,254 — 2.6% less here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 110 km. 9.59 m between rows, pitch 13.46 m (latitude 47.1°).
- Yield of 1 kWp
- 1,221kWh/year
- Tilt
- 36°1° east of south
- 10 kW
- 12,212kWh/year
- Row pitch
- 13.46m · GCR 0.36
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,110 / 460Pa
Ground frame designer
A ground frame for a solar plant: Zamistia
The designer opens with this place’s coordinates, latitude 47.1° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 110 km: snow 1,110 Pa, wind 460 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
August: 152 kWh/kWp, December: 34 — 4.5 times less.
January: 40 against 37 in the oblast, 8.1% more.
| kWp | A year | August | December |
|---|---|---|---|
| 5 | 6,106 | 760 | 170 |
| 10 | 12,212 | 1,520 | 340 |
| 15 | 18,318 | 2,280 | 510 |
Example: a 10 kW ground frame
For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.
How these numbers are computed
Nearby
- Oleksandrivka4 km1,221 kWh/kWp
- Boiove4 km1,217 kWh/kWp
- Bohdanivka5 km1,216 kWh/kWp
- Kalynivka5 km1,220 kWh/kWp
- Shardau6 km1,220 kWh/kWp
- Iline7 km1,220 kWh/kWp
All places: Berdianskyi RaionZaporizhzhia Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.