Solar plant: site data

Solar power plant in Ukromne, Zaporizkyi Raion, Zaporizhzhia Oblast

Ukromne: 1,193 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 1.6% below the oblast median (1,212). #158 of 286 in the rayon, #713 of 972 in the oblast.

Zaporizhzhya, the rayon centre, is 42 km away. 140 m above sea level. 19 km away: Novomykolayivka, the nearest bigger centre, the same 1,188. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 41 km. 10.13 m between rows, pitch 14.00 m (latitude 47.9°).

Yield of 1 kWp
1,193kWh/year
Tilt
36°2° east of south
10 kW
11,928kWh/year
Row pitch
14.00m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Ukromne

The designer opens with this place’s coordinates, latitude 47.9° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 41 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

36Jan55Feb96Mar118Apr140May144Jun152Jul153Aug125Sep94Oct51Nov29Dec

August: 153 kWh/kWp, December: 29 — 5.3 times less.

December: 29 against 32 in the oblast, 9.4% less.

Ukromne: plants, kWh
kWpA yearAugustDecember
55,964765145
1011,9281,530290
1517,8922,295435

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Zaporizkyi RaionZaporizhzhia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.