Solar plant: site data

Solar power plant in Terpinnia, Melitopolskyi Raion, Zaporizhzhia Oblast

Terpinnia: 1,226 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). 1.2% above the oblast median (1,212). #149 of 215 in the rayon, #248 of 972 in the oblast.

Melitopol, the rayon centre, is 15 km away. 27 m above sea level. 15 km away: Melitopol, the nearest bigger centre, 1,243 — 1.4% less here. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 98 km. 9.54 m between rows, pitch 13.41 m (latitude 47.0°).

Yield of 1 kWp
1,226kWh/year
Tilt
36°3° east of south
10 kW
12,260kWh/year
Row pitch
13.41m · GCR 0.36
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Terpinnia

The designer opens with this place’s coordinates, latitude 47.0° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 98 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

41Jan58Feb101Mar122Apr143May143Jun152Jul153Aug127Sep96Oct55Nov34Dec

August: 153 kWh/kWp, December: 34 — 4.5 times less.

January: 41 against 37 in the oblast, 10.8% more.

Terpinnia: plants, kWh
kWpA yearAugustDecember
56,130765170
1012,2601,530340
1518,3902,295510

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Melitopolskyi RaionZaporizhzhia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.