Solar plant: site data

Solar power plant in Shevchenkove, Polohivskyi Raion, Zaporizhzhia Oblast

Shevchenkove: 1,198 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 1.1% below the oblast median (1,212). #95 of 249 in the rayon, #628 of 972 in the oblast.

Polohy, the rayon centre, is 13 km away. 147 m above sea level. 13 km away: Polohy, the nearest bigger centre, the same 1,199. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 93 km. 9.79 m between rows, pitch 13.66 m (latitude 47.4°).

Yield of 1 kWp
1,198kWh/year
Tilt
36°2° east of south
10 kW
11,983kWh/year
Row pitch
13.66m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Shevchenkove

The designer opens with this place’s coordinates, latitude 47.4° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 93 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan56Feb96Mar119Apr140May141Jun151Jul151Aug125Sep97Oct54Nov31Dec

July: 151 kWh/kWp, December: 31 — 4.9 times less.

December: 31 against 32 in the oblast, 3.1% less.

Shevchenkove: plants, kWh
kWpA yearJulyDecember
55,992755155
1011,9831,510310
1517,9752,265465

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Polohivskyi RaionZaporizhzhia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.