Solar plant: site data

Solar power plant in Shevchenko, Polohivskyi Raion, Zaporizhzhia Oblast

Shevchenko: 1,191 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 1.8% below the oblast median (1,212). #143 of 249 in the rayon, #776 of 972 in the oblast.

Polohy, the rayon centre, is 30 km away. 131 m above sea level. 9 km away: Hulyaypole, the nearest bigger centre, the same 1,193. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 85 km. 10.04 m between rows, pitch 13.91 m (latitude 47.8°).

Yield of 1 kWp
1,191kWh/year
Tilt
36°2° east of south
10 kW
11,905kWh/year
Row pitch
13.91m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Shevchenko

The designer opens with this place’s coordinates, latitude 47.8° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 85 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan57Feb96Mar118Apr139May142Jun150Jul151Aug124Sep95Oct52Nov30Dec

August: 151 kWh/kWp, December: 30 — 5.0 times less.

December: 30 against 32 in the oblast, 6.3% less.

Shevchenko: plants, kWh
kWpA yearAugustDecember
55,953755150
1011,9051,510300
1517,8582,265450

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Polohivskyi RaionZaporizhzhia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.