Solar plant: site data

Solar power plant in Richne, Zaporizkyi Raion, Zaporizhzhia Oblast

Richne: 1,229 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 1.4% above the oblast median (1,212). #12 of 286 in the rayon, #212 of 972 in the oblast.

Zaporizhzhya, the rayon centre, is 25 km away. 28 m above sea level. 25 km away: Zaporizhzhya, the nearest bigger centre, the same 1,227. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 23 km. 9.99 m between rows, pitch 13.86 m (latitude 47.7°).

Yield of 1 kWp
1,229kWh/year
Tilt
36°1° east of south
10 kW
12,290kWh/year
Row pitch
13.86m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Richne

The designer opens with this place’s coordinates, latitude 47.7° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 23 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan58Feb100Mar124Apr144May148Jun156Jul154Aug126Sep96Oct53Nov32Dec

July: 156 kWh/kWp, December: 32 — 4.9 times less.

June: 148 against 144 in the oblast, 2.8% more.

Richne: plants, kWh
kWpA yearJulyDecember
56,145780160
1012,2901,560320
1518,4352,340480

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.