Solar plant: site data

Solar power plant in Pshenychne, Polohivskyi Raion, Zaporizhzhia Oblast

Pshenychne: 1,208 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). Exactly the oblast median (1,212). #50 of 249 in the rayon, #514 of 972 in the oblast.

Polohy, the rayon centre, is 33 km away. 117 m above sea level. 24 km away: Orikhiv, the nearest bigger centre, the same 1,208. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 75 km. 9.78 m between rows, pitch 13.65 m (latitude 47.4°).

Yield of 1 kWp
1,208kWh/year
Tilt
36°1° east of south
10 kW
12,078kWh/year
Row pitch
13.65m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Pshenychne

The designer opens with this place’s coordinates, latitude 47.4° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 75 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan57Feb99Mar120Apr140May142Jun151Jul151Aug126Sep96Oct54Nov33Dec

July: 151 kWh/kWp, December: 33 — 4.6 times less.

December: 33 against 32 in the oblast, 3.1% more.

Pshenychne: plants, kWh
kWpA yearJulyDecember
56,039755165
1012,0781,510330
1518,1172,265495

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Polohivskyi RaionZaporizhzhia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.