Solar plant: site data

Solar power plant in Harasivka, Zaporizkyi Raion, Zaporizhzhia Oblast

Harasivka: 1,196 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 1.3% below the oblast median (1,212). #126 of 286 in the rayon, #671 of 972 in the oblast.

Zaporizhzhya, the rayon centre, is 22 km away. 119 m above sea level. 5 km away: Vilnyansk, the nearest bigger centre, the same 1,191. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 21 km. 10.18 m between rows, pitch 14.05 m (latitude 48.0°).

Yield of 1 kWp
1,196kWh/year
Tilt
36°2° east of south
10 kW
11,958kWh/year
Row pitch
14.05m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Harasivka

The designer opens with this place’s coordinates, latitude 48.0° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 21 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan59Feb96Mar119Apr140May145Jun152Jul152Aug124Sep93Oct50Nov29Dec

July: 152 kWh/kWp, December: 29 — 5.2 times less.

December: 29 against 32 in the oblast, 9.4% less.

Harasivka: plants, kWh
kWpA yearJulyDecember
55,979760145
1011,9581,520290
1517,9372,280435

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Zaporizkyi RaionZaporizhzhia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.