Solar plant: site data

Solar power plant in Baburka, Zaporizkyi Raion, Zaporizhzhia Oblast

Baburka: 1,231 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 1.6% above the oblast median (1,212). #8 of 286 in the rayon, #193 of 972 in the oblast.

Zaporizhzhya, the rayon centre, is 7 km away. 78 m above sea level. 7 km away: Zaporizhzhya, the nearest bigger centre, the same 1,227. Snow and wind from the nearest regional centre in the DBN — Запоріжжя, 7 km. 10.31 m between rows, pitch 14.13 m (latitude 47.8°).

Yield of 1 kWp
1,231kWh/year
Tilt
37°1° east of south
10 kW
12,313kWh/year
Row pitch
14.13m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,110 / 460Pa

Ground frame designer

A ground frame for a solar plant: Baburka

The designer opens with this place’s coordinates, latitude 47.8° for the row spacing and the DBN loads of the nearest regional centre — Запоріжжя, 7 km: snow 1,110 Pa, wind 460 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

42Jan62Feb100Mar123Apr145May147Jun153Jul153Aug126Sep94Oct53Nov33Dec

July: 153 kWh/kWp, December: 33 — 4.6 times less.

January: 42 against 37 in the oblast, 13.5% more.

Baburka: plants, kWh
kWpA yearJulyDecember
56,157765165
1012,3131,530330
1518,4702,295495

Snow and wind: Запоріжжя

Example: a 10 kW ground frame

For the loads of Zaporizhzhia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Zaporizkyi RaionZaporizhzhia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.