Solar plant: site data

Solar power plant in Zbyny, Mukachivskyi Raion, Zakarpattia Oblast

Zbyny: 1,062 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 6.9% below the oblast median (1,141). #123 of 139 in the rayon, #505 of 613 in the oblast.

Mukachevo, the rayon centre, is 42 km away. 449 m above sea level. 35 km away: Perechyn, the nearest bigger centre, 1,100 — 3.5% less here. Snow and wind from the nearest regional centre in the DBN — Ужгород, 51 km. 10.79 m between rows, pitch 14.66 m (latitude 48.8°).

Yield of 1 kWp
1,062kWh/year
Tilt
36°2° east of south
10 kW
10,620kWh/year
Row pitch
14.66m · GCR 0.33
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,340 / 370Pa

Ground frame designer

A ground frame for a solar plant: Zbyny

The designer opens with this place’s coordinates, latitude 48.8° for the row spacing and the DBN loads of the nearest regional centre — Ужгород, 51 km: snow 1,340 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan56Feb91Mar108Apr121May127Jun133Jul132Aug105Sep79Oct45Nov27Dec

July: 133 kWh/kWp, December: 27 — 4.9 times less.

November: 45 against 53 in the oblast, 15.1% less.

Zbyny: plants, kWh
kWpA yearJulyDecember
55,310665135
1010,6201,330270
1515,9301,995405

Snow and wind: Ужгород

Example: a 10 kW ground frame

For the loads of Uzhhorod: 11.16 kWp, 18 panels, 366 kg of steel, 12 piles, materials ≈ 48,597 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mukachivskyi RaionZakarpattia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.