Solar plant: site data
Solar power plant in Kobyletska Polyana, Rakhivskyi Raion, Zakarpattia Oblast
Kobyletska Polyana: 1,092 kWh per kWp a year, tilt 36° facing south (PVGIS). 4.3% below the oblast median (1,141). #11 of 36 in the rayon, #458 of 613 in the oblast.
Rakhiv, the rayon centre, is 10 km away. 411 m above sea level. 10 km away: Rakhiv, the nearest bigger centre, 1,068 — 2.3% more here. Snow and wind from the nearest regional centre in the DBN — Івано-Франківськ, 107 km. 10.25 m between rows, pitch 14.12 m (latitude 48.1°).
- Yield of 1 kWp
- 1,092kWh/year
- Tilt
- 36°facing south
- 10 kW
- 10,922kWh/year
- Row pitch
- 14.12m · GCR 0.34
- T_min
- -38 °Cregion IIIA, Carpathian
- Snow S₀ / wind W₀
- 1,410 / 500Pa
Ground frame designer
A ground frame for a solar plant: Kobyletska Polyana
The designer opens with this place’s coordinates, latitude 48.1° for the row spacing and the DBN loads of the nearest regional centre — Івано-Франківськ, 107 km: snow 1,410 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
August: 137 kWh/kWp, December: 29 — 4.7 times less.
April: 108 against 117 in the oblast, 7.7% less.
| kWp | A year | August | December |
|---|---|---|---|
| 5 | 5,461 | 685 | 145 |
| 10 | 10,922 | 1,370 | 290 |
| 15 | 16,383 | 2,055 | 435 |
Snow and wind: Івано-Франківськ
Example: a 10 kW ground frame
For the loads of Ivano-Frankivsk: 11.16 kWp, 18 panels, 410 kg of steel, 16 piles, materials ≈ 54,212 UAH.
How these numbers are computed
Nearby
- Kosivska Poliana7 km1,073 kWh/kWp
- Rosishka8 km1,116 kWh/kWp
- Vodytsia9 km1,117 kWh/kWp
- Vilkhovatyi9 km1,067 kWh/kWp
- Rakhiv10 km1,068 kWh/kWp
- Plaiuts10 km1,119 kWh/kWp
All places: Rakhivskyi RaionZakarpattia Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.