Solar plant: site data

Solar power plant in Velykyi Obzyr, Kamin-Kashyrskyi Raion, Volyn Oblast

Velykyi Obzyr: 1,053 kWh per kWp a year, tilt 39° 5° east of south (PVGIS). 2.9% below the oblast median (1,084). #135 of 167 in the rayon, #1087 of 1120 in the oblast.

Kamin-Kashyrskyi, the rayon centre, is 26 km away. 155 m above sea level. 26 km away: Kamin-Kashyrskyi, the nearest bigger centre, the same 1,058. Snow and wind from the nearest regional centre in the DBN — Луцьк, 79 km. 14.23 m between rows, pitch 17.95 m (latitude 51.5°).

Yield of 1 kWp
1,053kWh/year
Tilt
39°5° east of south
10 kW
10,527kWh/year
Row pitch
17.95m · GCR 0.27
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,240 / 480Pa

Ground frame designer

A ground frame for a solar plant: Velykyi Obzyr

The designer opens with this place’s coordinates, latitude 51.5° for the row spacing and the DBN loads of the nearest regional centre — Луцьк, 79 km: snow 1,240 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan52Feb93Mar113Apr125May130Jun131Jul132Aug104Sep76Oct35Nov27Dec

August: 132 kWh/kWp, December: 27 — 4.9 times less.

November: 35 against 37 in the oblast, 5.4% less.

Velykyi Obzyr: plants, kWh
kWpA yearAugustDecember
55,264660135
1010,5271,320270
1515,7911,980405

Snow and wind: Луцьк

Example: a 10 kW ground frame

For the loads of Lutsk: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 50,491 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamin-Kashyrskyi RaionVolyn Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.