Solar plant: site data

Solar power plant in Dovzhytsia, Kamin-Kashyrskyi Raion, Volyn Oblast

Dovzhytsia: 1,064 kWh per kWp a year, tilt 38° 3° east of south (PVGIS). 1.9% below the oblast median (1,084). #95 of 167 in the rayon, #987 of 1120 in the oblast.

Kamin-Kashyrskyi, the rayon centre, is 63 km away. 170 m above sea level. 27 km away: Varash, the nearest bigger centre, the same 1,067. Snow and wind from the nearest regional centre in the DBN — Луцьк, 51 km. 13.61 m between rows, pitch 17.38 m (latitude 51.2°).

Yield of 1 kWp
1,064kWh/year
Tilt
38°3° east of south
10 kW
10,638kWh/year
Row pitch
17.38m · GCR 0.28
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,240 / 480Pa

Ground frame designer

A ground frame for a solar plant: Dovzhytsia

The designer opens with this place’s coordinates, latitude 51.2° for the row spacing and the DBN loads of the nearest regional centre — Луцьк, 51 km: snow 1,240 Pa, wind 480 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

33Jan51Feb92Mar115Apr127May133Jun132Jul134Aug105Sep77Oct36Nov27Dec

August: 134 kWh/kWp, December: 27 — 5.0 times less.

October: 77 against 80 in the oblast, 3.8% less.

Dovzhytsia: plants, kWh
kWpA yearAugustDecember
55,319670135
1010,6381,340270
1515,9572,010405

Snow and wind: Луцьк

Example: a 10 kW ground frame

For the loads of Lutsk: 11.16 kWp, 18 panels, 376 kg of steel, 12 piles, materials ≈ 50,491 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kamin-Kashyrskyi RaionVolyn Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.