Solar plant: site data

Solar power plant in Ulyanivka, Mohyliv-Podilskyi Raion, Vinnytsia Oblast

Ulyanivka: 1,167 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 2.1% above the oblast median (1,143). #6 of 158 in the rayon, #43 of 1206 in the oblast.

Mohyliv-Podilskyy, the rayon centre, is 40 km away. 58 m above sea level. 40 km away: Mohyliv-Podilskyy, the nearest bigger centre, 1,160 — 0.6% more here. Snow and wind from the nearest regional centre in the DBN — Вінниця, 113 km. 10.37 m between rows, pitch 14.24 m (latitude 48.2°).

Yield of 1 kWp
1,167kWh/year
Tilt
36°2° east of south
10 kW
11,671kWh/year
Row pitch
14.24m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Ulyanivka

The designer opens with this place’s coordinates, latitude 48.2° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 113 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

40Jan52Feb99Mar121Apr137May139Jun145Jul144Aug118Sep91Oct46Nov35Dec

July: 145 kWh/kWp, December: 35 — 4.1 times less.

January: 40 against 36 in the oblast, 12.7% more.

Ulyanivka: plants, kWh
kWpA yearJulyDecember
55,836725175
1011,6711,450350
1517,5072,175525

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mohyliv-Podilskyi RaionVinnytsia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.