Solar plant: site data

Solar power plant in Tropove, Mohyliv-Podilskyi Raion, Vinnytsia Oblast

Tropove: 1,149 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 0.5% above the oblast median (1,143). #116 of 158 in the rayon, #414 of 1206 in the oblast.

Mohyliv-Podilskyy, the rayon centre, is 26 km away. 236 m above sea level. 26 km away: Mohyliv-Podilskyy, the nearest bigger centre, 1,160 — 0.9% less here. Snow and wind from the nearest regional centre in the DBN — Вінниця, 75 km. 10.68 m between rows, pitch 14.55 m (latitude 48.7°).

Yield of 1 kWp
1,149kWh/year
Tilt
36°2° east of south
10 kW
11,487kWh/year
Row pitch
14.55m · GCR 0.33
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Tropove

The designer opens with this place’s coordinates, latitude 48.7° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 75 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

34Jan53Feb91Mar122Apr139May141Jun144Jul143Aug118Sep89Oct43Nov33Dec

July: 144 kWh/kWp, December: 33 — 4.4 times less.

November: 43 against 41 in the oblast, 4.9% more.

Tropove: plants, kWh
kWpA yearJulyDecember
55,744720165
1011,4871,440330
1517,2312,160495

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 346 kg of steel, 12 piles, materials ≈ 51,820 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mohyliv-Podilskyi RaionVinnytsia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.