Solar plant: site data
Solar power plant in Tereshki, Zhmerynskyi Raion, Vinnytsia Oblast
Tereshki: 1,131 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 1.0% below the oblast median (1,143). #117 of 151 in the rayon, #802 of 1206 in the oblast.
Zhmerynka, the rayon centre, is 36 km away. 316 m above sea level. 28 km away: Vinkivtsi, the nearest bigger centre, the same 1,127. Snow and wind from the nearest regional centre in the DBN — Хмельницький, 64 km. 10.97 m between rows, pitch 14.84 m (latitude 49.0°).
- Yield of 1 kWp
- 1,131kWh/year
- Tilt
- 36°1° east of south
- 10 kW
- 11,312kWh/year
- Row pitch
- 14.84m · GCR 0.32
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,340 / 500Pa
Ground frame designer
A ground frame for a solar plant: Tereshki
The designer opens with this place’s coordinates, latitude 49.0° for the row spacing and the DBN loads of the nearest regional centre — Хмельницький, 64 km: snow 1,340 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 143 kWh/kWp, December: 31 — 4.6 times less.
March: 89 against 92 in the oblast, 3.3% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,656 | 715 | 155 |
| 10 | 11,312 | 1,430 | 310 |
| 15 | 16,968 | 2,145 | 465 |
Example: a 10 kW ground frame
For the loads of Khmelnytskyi: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.
How these numbers are computed
Nearby
- Zhuravlivka2 km1,128 kWh/kWp
- Semenki3 km1,132 kWh/kWp
- Seferivka4 km1,132 kWh/kWp
- Okladne4 km1,132 kWh/kWp
- Paliivka6 km1,132 kWh/kWp
- Myhalivtsi6 km1,128 kWh/kWp
All places: Zhmerynskyi RaionVinnytsia Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.