Solar plant: site data

Solar power plant in Sadky, Mohyliv-Podilskyi Raion, Vinnytsia Oblast

Sadky: 1,156 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). 1.2% above the oblast median (1,143). #66 of 158 in the rayon, #229 of 1206 in the oblast.

Mohyliv-Podilskyy, the rayon centre, is 15 km away. 200 m above sea level. 15 km away: Mohyliv-Podilskyy, the nearest bigger centre, the same 1,160. Snow and wind from the nearest regional centre in the DBN — Вінниця, 91 km. 10.55 m between rows, pitch 14.42 m (latitude 48.5°).

Yield of 1 kWp
1,156kWh/year
Tilt
36°3° east of south
10 kW
11,564kWh/year
Row pitch
14.42m · GCR 0.33
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Sadky

The designer opens with this place’s coordinates, latitude 48.5° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 91 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

39Jan52Feb94Mar121Apr138May140Jun143Jul142Aug117Sep90Oct44Nov35Dec

July: 143 kWh/kWp, December: 35 — 4.1 times less.

January: 39 against 36 in the oblast, 9.9% more.

Sadky: plants, kWh
kWpA yearJulyDecember
55,782715175
1011,5641,430350
1517,3462,145525

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mohyliv-Podilskyi RaionVinnytsia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.