Solar plant: site data

Solar power plant in Levkivtsi, Tulchynskyi Raion, Vinnytsia Oblast

Levkivtsi: 1,152 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 0.8% above the oblast median (1,143). #130 of 184 in the rayon, #316 of 1206 in the oblast.

Tulchyn, the rayon centre, is 26 km away. 257 m above sea level. 26 km away: Tulchyn, the nearest bigger centre, the same 1,156. Snow and wind from the nearest regional centre in the DBN — Вінниця, 54 km. 10.75 m between rows, pitch 14.62 m (latitude 48.7°).

Yield of 1 kWp
1,152kWh/year
Tilt
36°2° east of south
10 kW
11,524kWh/year
Row pitch
14.62m · GCR 0.33
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Levkivtsi

The designer opens with this place’s coordinates, latitude 48.7° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 54 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan53Feb95Mar120Apr138May140Jun144Jul142Aug117Sep88Oct43Nov35Dec

July: 144 kWh/kWp, December: 35 — 4.1 times less.

December: 35 against 32 in the oblast, 9.4% more.

Levkivtsi: plants, kWh
kWpA yearJulyDecember
55,762720175
1011,5241,440350
1517,2862,160525

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Tulchynskyi RaionVinnytsia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.