Solar plant: site data

Solar power plant in Levkiv, Tulchynskyi Raion, Vinnytsia Oblast

Levkiv: 1,167 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 2.1% above the oblast median (1,143). #19 of 184 in the rayon, #49 of 1206 in the oblast.

Tulchyn, the rayon centre, is 30 km away. 206 m above sea level. 30 km away: Tulchyn, the nearest bigger centre, 1,156 — 1.0% more here. Snow and wind from the nearest regional centre in the DBN — Вінниця, 98 km. 10.77 m between rows, pitch 14.59 m (latitude 48.4°).

Yield of 1 kWp
1,167kWh/year
Tilt
37°2° east of south
10 kW
11,669kWh/year
Row pitch
14.59m · GCR 0.33
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Levkiv

The designer opens with this place’s coordinates, latitude 48.4° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 98 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

40Jan55Feb97Mar121Apr138May141Jun146Jul144Aug118Sep90Oct44Nov34Dec

July: 146 kWh/kWp, December: 34 — 4.3 times less.

January: 40 against 36 in the oblast, 12.7% more.

Levkiv: plants, kWh
kWpA yearJulyDecember
55,835730170
1011,6691,460340
1517,5042,190510

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Tulchynskyi RaionVinnytsia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.