Solar plant: site data

Solar power plant in Kozliv, Mohyliv-Podilskyi Raion, Vinnytsia Oblast

Kozliv: 1,154 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 1.0% above the oblast median (1,143). #79 of 158 in the rayon, #264 of 1206 in the oblast.

Mohyliv-Podilskyy, the rayon centre, is 21 km away. 68 m above sea level. 21 km away: Mohyliv-Podilskyy, the nearest bigger centre, the same 1,160. Snow and wind from the nearest regional centre in the DBN — Вінниця, 109 km. 10.55 m between rows, pitch 14.42 m (latitude 48.5°).

Yield of 1 kWp
1,154kWh/year
Tilt
36°1° east of south
10 kW
11,544kWh/year
Row pitch
14.42m · GCR 0.33
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Kozliv

The designer opens with this place’s coordinates, latitude 48.5° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 109 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan52Feb96Mar121Apr138May138Jun145Jul142Aug117Sep90Oct44Nov34Dec

July: 145 kWh/kWp, December: 34 — 4.3 times less.

November: 44 against 41 in the oblast, 7.3% more.

Kozliv: plants, kWh
kWpA yearJulyDecember
55,772725170
1011,5441,450340
1517,3162,175510

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mohyliv-Podilskyi RaionVinnytsia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.