Solar plant: site data

Solar power plant in Babyna Dolyna, Zhmerynskyi Raion, Vinnytsia Oblast

Babyna Dolyna: 1,137 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). Exactly the oblast median (1,143). #88 of 151 in the rayon, #707 of 1206 in the oblast.

Zhmerynka, the rayon centre, is 17 km away. 298 m above sea level. 17 km away: Zhmerynka, the nearest bigger centre, the same 1,136. Snow and wind from the nearest regional centre in the DBN — Вінниця, 39 km. 10.88 m between rows, pitch 14.75 m (latitude 48.9°).

Yield of 1 kWp
1,137kWh/year
Tilt
36°1° east of south
10 kW
11,374kWh/year
Row pitch
14.75m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,360 / 470Pa

Ground frame designer

A ground frame for a solar plant: Babyna Dolyna

The designer opens with this place’s coordinates, latitude 48.9° for the row spacing and the DBN loads of the nearest regional centre — Вінниця, 39 km: snow 1,360 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan50Feb90Mar120Apr138May141Jun143Jul142Aug115Sep88Oct41Nov33Dec

July: 143 kWh/kWp, December: 33 — 4.3 times less.

February: 50 against 52 in the oblast, 3.8% less.

Babyna Dolyna: plants, kWh
kWpA yearJulyDecember
55,687715165
1011,3741,430330
1517,0612,145495

Snow and wind: Вінниця

Example: a 10 kW ground frame

For the loads of Vinnytsia: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Zhmerynskyi RaionVinnytsia Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.