Solar power plant in Vovkivtsi, Chortkivskyi Raion, Ternopil Oblast

Vovkivtsi: 1,122 kWh per kWp a year, tilt 37° 4° east of south (PVGIS). 2.7% above the oblast median (1,093). #94 of 296 in the rayon, #94 of 744 in the oblast.

Chortkiv, the rayon centre, is 35 km away. 230 m above sea level. 33 km away: Zastavna, the nearest bigger centre, 1,131 — 0.8% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 55 km. 11.03 m between rows, pitch 14.85 m (latitude 48.8°).

Yield of 1 kWp
1,122kWh/year
Tilt
37°4° east of south
10 kW
11,223kWh/year
Row pitch
14.85m · GCR 0.32
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Vovkivtsi

The designer opens with this place’s coordinates, latitude 48.8° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 55 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

41Jan54Feb95Mar118Apr133May133Jun140Jul137Aug112Sep86Oct40Nov33Dec

July: 140 kWh/kWp, December: 33 — 4.2 times less.

January: 41 against 34 in the oblast, 20.6% more.

Vovkivtsi: plants, kWh
kWpA yearJulyDecember
55,612700165
1011,2231,400330
1516,8352,100495

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chortkivskyi RaionTernopil Oblast: rayons and towns

Free calculators

Sources