Solar plant: site data

Solar power plant in Vilkhivchyk, Chortkivskyi Raion, Ternopil Oblast

Vilkhivchyk: 1,106 kWh per kWp a year, tilt 36° 1° east of south (PVGIS). 1.2% above the oblast median (1,093). #247 of 296 in the rayon, #253 of 744 in the oblast.

Chortkiv, the rayon centre, is 30 km away. 241 m above sea level. 28 km away: Horodok, the nearest bigger centre, the same 1,101. Snow and wind from the nearest regional centre in the DBN — Тернопіль, 67 km. 11.03 m between rows, pitch 14.90 m (latitude 49.1°).

Yield of 1 kWp
1,106kWh/year
Tilt
36°1° east of south
10 kW
11,060kWh/year
Row pitch
14.90m · GCR 0.32
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,390 / 520Pa

Ground frame designer

A ground frame for a solar plant: Vilkhivchyk

The designer opens with this place’s coordinates, latitude 49.1° for the row spacing and the DBN loads of the nearest regional centre — Тернопіль, 67 km: snow 1,390 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan52Feb91Mar117Apr132May135Jun140Jul138Aug113Sep85Oct38Nov30Dec

July: 140 kWh/kWp, December: 30 — 4.7 times less.

January: 35 against 34 in the oblast, 2.9% more.

Vilkhivchyk: plants, kWh
kWpA yearJulyDecember
55,530700150
1011,0601,400300
1516,5902,100450

Snow and wind: Тернопіль

Example: a 10 kW ground frame

For the loads of Ternopil: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chortkivskyi RaionTernopil Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.