Solar plant: site data
Solar power plant in Syniava, Ternopilskyi Raion, Ternopil Oblast
Syniava: 1,084 kWh per kWp a year, tilt 36° 2° east of south (PVGIS). 0.8% below the oblast median (1,093). #177 of 313 in the rayon, #516 of 744 in the oblast.
Ternopil, the rayon centre, is 27 km away. 331 m above sea level. 9 km away: Zbarazh, the nearest bigger centre, 1,078 — 0.6% more here. Snow and wind from the nearest regional centre in the DBN — Тернопіль, 28 km. 11.55 m between rows, pitch 15.42 m (latitude 49.7°).
- Yield of 1 kWp
- 1,084kWh/year
- Tilt
- 36°2° east of south
- 10 kW
- 10,843kWh/year
- Row pitch
- 15.42m · GCR 0.31
- T_min
- -40 °Cregion I, north-western
- Snow S₀ / wind W₀
- 1,390 / 520Pa
Ground frame designer
A ground frame for a solar plant: Syniava
The designer opens with this place’s coordinates, latitude 49.7° for the row spacing and the DBN loads of the nearest regional centre — Тернопіль, 28 km: snow 1,390 Pa, wind 520 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 138 kWh/kWp, December: 30 — 4.6 times less.
February: 48 against 53 in the oblast, 9.4% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,422 | 690 | 150 |
| 10 | 10,843 | 1,380 | 300 |
| 15 | 16,265 | 2,070 | 450 |
Example: a 10 kW ground frame
For the loads of Ternopil: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.
How these numbers are computed
Nearby
- Krasnosiltsi4 km1,082 kWh/kWp
- Kapustintsy4 km1,082 kWh/kWp
- Nyzhchi Lubianky6 km1,078 kWh/kWp
- Vyshchi Lubianky6 km1,081 kWh/kWp
- Vereshchaky7 km1,087 kWh/kWp
- Shymkivtsi8 km1,080 kWh/kWp
All places: Ternopilskyi RaionTernopil Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.