Solar plant: site data

Solar power plant in Soroky, Chortkivskyi Raion, Ternopil Oblast

Soroky: 1,112 kWh per kWp a year, tilt 37° 3° east of south (PVGIS). 1.7% above the oblast median (1,093). #194 of 296 in the rayon, #195 of 744 in the oblast.

Chortkiv, the rayon centre, is 31 km away. 340 m above sea level. 31 km away: Chortkiv, the nearest bigger centre, 1,126 — 1.3% less here. Snow and wind from the nearest regional centre in the DBN — Івано-Франківськ, 49 km. 11.22 m between rows, pitch 15.04 m (latitude 49.0°).

Yield of 1 kWp
1,112kWh/year
Tilt
37°3° east of south
10 kW
11,115kWh/year
Row pitch
15.04m · GCR 0.32
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,410 / 500Pa

Ground frame designer

A ground frame for a solar plant: Soroky

The designer opens with this place’s coordinates, latitude 49.0° for the row spacing and the DBN loads of the nearest regional centre — Івано-Франківськ, 49 km: snow 1,410 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

40Jan55Feb97Mar116Apr129May130Jun137Jul135Aug111Sep86Oct41Nov35Dec

July: 137 kWh/kWp, December: 35 — 3.9 times less.

January: 40 against 34 in the oblast, 17.6% more.

Soroky: plants, kWh
kWpA yearJulyDecember
55,558685175
1011,1151,370350
1516,6732,055525

Snow and wind: Івано-Франківськ

Example: a 10 kW ground frame

For the loads of Ivano-Frankivsk: 11.16 kWp, 18 panels, 410 kg of steel, 16 piles, materials ≈ 54,212 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chortkivskyi RaionTernopil Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.