Solar plant: site data

Solar power plant in Myshkiv, Chortkivskyi Raion, Ternopil Oblast

Myshkiv: 1,086 kWh per kWp a year, tilt 34° facing south (PVGIS). 0.6% below the oblast median (1,093). #294 of 296 in the rayon, #491 of 744 in the oblast.

Chortkiv, the rayon centre, is 27 km away. 214 m above sea level. 27 km away: Chortkiv, the nearest bigger centre, 1,126 — 3.6% less here. Snow and wind from the nearest regional centre in the DBN — Чернівці, 55 km. 10.25 m between rows, pitch 14.22 m (latitude 48.8°).

Yield of 1 kWp
1,086kWh/year
Tilt
34°facing south
10 kW
10,856kWh/year
Row pitch
14.22m · GCR 0.34
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,320 / 500Pa

Ground frame designer

A ground frame for a solar plant: Myshkiv

The designer opens with this place’s coordinates, latitude 48.8° for the row spacing and the DBN loads of the nearest regional centre — Чернівці, 55 km: snow 1,320 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

31Jan50Feb94Mar117Apr132May133Jun140Jul136Aug113Sep83Oct36Nov21Dec

July: 140 kWh/kWp, December: 21 — 6.7 times less.

December: 21 against 30 in the oblast, 30.0% less.

Myshkiv: plants, kWh
kWpA yearJulyDecember
55,428700105
1010,8561,400210
1516,2842,100315

Snow and wind: Чернівці

Example: a 10 kW ground frame

For the loads of Chernivtsi: 11.16 kWp, 18 panels, 412 kg of steel, 16 piles, materials ≈ 54,638 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chortkivskyi RaionTernopil Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.