Solar plant: site data

Solar power plant in Loshniv, Ternopilskyi Raion, Ternopil Oblast

Loshniv: 1,100 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 0.7% above the oblast median (1,093). #23 of 313 in the rayon, #297 of 744 in the oblast.

Ternopil, the rayon centre, is 23 km away. 285 m above sea level. 7 km away: Terebovlia, the nearest bigger centre, the same 1,104. Snow and wind from the nearest regional centre in the DBN — Тернопіль, 23 km. 11.51 m between rows, pitch 15.33 m (latitude 49.4°).

Yield of 1 kWp
1,100kWh/year
Tilt
37°1° east of south
10 kW
10,997kWh/year
Row pitch
15.33m · GCR 0.31
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,390 / 520Pa

Ground frame designer

A ground frame for a solar plant: Loshniv

The designer opens with this place’s coordinates, latitude 49.4° for the row spacing and the DBN loads of the nearest regional centre — Тернопіль, 23 km: snow 1,390 Pa, wind 520 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan53Feb93Mar117Apr130May134Jun138Jul134Aug112Sep84Oct38Nov30Dec

July: 138 kWh/kWp, December: 30 — 4.6 times less.

January: 35 against 34 in the oblast, 2.9% more.

Loshniv: plants, kWh
kWpA yearJulyDecember
55,499690150
1010,9971,380300
1516,4962,070450

Snow and wind: Тернопіль

Example: a 10 kW ground frame

For the loads of Ternopil: 11.16 kWp, 18 panels, 415 kg of steel, 16 piles, materials ≈ 55,054 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Ternopilskyi RaionTernopil Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.