Solar plant: site data

Solar power plant in Horozhanka, Chortkivskyi Raion, Ternopil Oblast

Horozhanka: 1,094 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). Exactly the oblast median (1,093). #286 of 296 in the rayon, #341 of 744 in the oblast.

Chortkiv, the rayon centre, is 65 km away. 252 m above sea level. 14 km away: Halych, the nearest bigger centre, 1,104 — 0.9% less here. Snow and wind from the nearest regional centre in the DBN — Івано-Франківськ, 29 km. 11.33 m between rows, pitch 15.15 m (latitude 49.1°).

Yield of 1 kWp
1,094kWh/year
Tilt
37°2° east of south
10 kW
10,941kWh/year
Row pitch
15.15m · GCR 0.32
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,410 / 500Pa

Ground frame designer

A ground frame for a solar plant: Horozhanka

The designer opens with this place’s coordinates, latitude 49.1° for the row spacing and the DBN loads of the nearest regional centre — Івано-Франківськ, 29 km: snow 1,410 Pa, wind 500 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

38Jan56Feb94Mar115Apr126May127Jun136Jul133Aug109Sep84Oct42Nov33Dec

July: 136 kWh/kWp, December: 33 — 4.1 times less.

January: 38 against 34 in the oblast, 11.8% more.

Horozhanka: plants, kWh
kWpA yearJulyDecember
55,471680165
1010,9411,360330
1516,4122,040495

Snow and wind: Івано-Франківськ

Example: a 10 kW ground frame

For the loads of Ivano-Frankivsk: 11.16 kWp, 18 panels, 410 kg of steel, 16 piles, materials ≈ 54,212 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Chortkivskyi RaionTernopil Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.