Solar plant: site data

Solar power plant in Pyrohivka, Shostkynskyi Raion, Sumy Oblast

Pyrohivka: 1,089 kWh per kWp a year, tilt 39° 2° east of south (PVGIS). 1.9% below the oblast median (1,110). #165 of 258 in the rayon, #1417 of 1534 in the oblast.

Shostka, the rayon centre, is 13 km away. 125 m above sea level. 11 km away: Novhorod-Siverskyi, the nearest bigger centre, the same 1,083. Snow and wind from the nearest regional centre in the DBN — Чернігів, 145 km. 14.81 m between rows, pitch 18.53 m (latitude 51.9°).

Yield of 1 kWp
1,089kWh/year
Tilt
39°2° east of south
10 kW
10,887kWh/year
Row pitch
18.53m · GCR 0.26
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,720 / 410Pa

Ground frame designer

A ground frame for a solar plant: Pyrohivka

The designer opens with this place’s coordinates, latitude 51.9° for the row spacing and the DBN loads of the nearest regional centre — Чернігів, 145 km: snow 1,720 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan59Feb98Mar114Apr138May140Jun137Jul135Aug106Sep71Oct31Nov24Dec

June: 140 kWh/kWp, December: 24 — 5.8 times less.

November: 31 against 35 in the oblast, 11.4% less.

Pyrohivka: plants, kWh
kWpA yearJuneDecember
55,444700120
1010,8871,400240
1516,3312,100360

Snow and wind: Чернігів

Example: a 10 kW ground frame

For the loads of Chernihiv: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Shostkynskyi RaionSumy Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.