Solar plant: site data

Solar power plant in Myronivshchyna, Sumskyi Raion, Sumy Oblast

Myronivshchyna: 1,110 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). Exactly the oblast median (1,110). #268 of 466 in the rayon, #768 of 1534 in the oblast.

Sumy, the rayon centre, is 38 km away. 181 m above sea level. 38 km away: Sumy, the nearest bigger centre, 1,117 — 0.7% less here. Snow and wind from the nearest regional centre in the DBN — Суми, 38 km. 12.86 m between rows, pitch 16.68 m (latitude 50.8°).

Yield of 1 kWp
1,110kWh/year
Tilt
37°1° east of south
10 kW
11,096kWh/year
Row pitch
16.68m · GCR 0.29
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,670 / 420Pa

Ground frame designer

A ground frame for a solar plant: Myronivshchyna

The designer opens with this place’s coordinates, latitude 50.8° for the row spacing and the DBN loads of the nearest regional centre — Суми, 38 km: snow 1,670 Pa, wind 420 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

36Jan58Feb89Mar115Apr139May143Jun145Jul142Aug110Sep76Oct35Nov22Dec

July: 145 kWh/kWp, December: 22 — 6.6 times less.

March: 89 against 95 in the oblast, 6.3% less.

Myronivshchyna: plants, kWh
kWpA yearJulyDecember
55,548725110
1011,0961,450220
1516,6442,175330

Snow and wind: Суми

Example: a 10 kW ground frame

For the loads of Sumy: 11.16 kWp, 18 panels, 385 kg of steel, 12 piles, materials ≈ 51,876 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Sumskyi RaionSumy Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.