Solar plant: site data

Solar power plant in Hlukhiv, Shostkynskyi Raion, Sumy Oblast

Hlukhiv: 1,105 kWh per kWp a year, tilt 39° 1° east of south (PVGIS). Exactly the oblast median (1,110). #14 of 258 in the rayon, #985 of 1534 in the oblast.

Shostka, the rayon centre, is 37 km away. 178 m above sea level. 37 km away: Shostka, the nearest bigger centre, 1,082 — 2.2% more here. Snow and wind from the nearest regional centre in the DBN — Суми, 105 km. 14.51 m between rows, pitch 18.23 m (latitude 51.7°).

Yield of 1 kWp
1,105kWh/year
Tilt
39°1° east of south
10 kW
11,050kWh/year
Row pitch
18.23m · GCR 0.26
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,670 / 420Pa

Ground frame designer

A ground frame for a solar plant: Hlukhiv

The designer opens with this place’s coordinates, latitude 51.7° for the row spacing and the DBN loads of the nearest regional centre — Суми, 105 km: snow 1,670 Pa, wind 420 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan61Feb97Mar115Apr140May143Jun140Jul137Aug107Sep71Oct34Nov24Dec

June: 143 kWh/kWp, December: 24 — 6.0 times less.

October: 71 against 75 in the oblast, 5.3% less.

Hlukhiv: plants, kWh
kWpA yearJuneDecember
55,525715120
1011,0501,430240
1516,5752,145360

Snow and wind: Суми

Example: a 10 kW ground frame

For the loads of Sumy: 11.16 kWp, 18 panels, 359 kg of steel, 12 piles, materials ≈ 53,991 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Shostkynskyi RaionSumy Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.