Solar plant: site data

Solar power plant in Vyshenky, Myrhorodskyi Raion, Poltava Oblast

Vyshenky: 1,134 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 0.7% below the oblast median (1,142). #182 of 430 in the rayon, #1340 of 1856 in the oblast.

Myrhorod, the rayon centre, is 60 km away. 162 m above sea level. 41 km away: Lubny, the nearest bigger centre, 1,146 — 1.1% less here. Snow and wind from the nearest regional centre in the DBN — Черкаси, 127 km. 12.45 m between rows, pitch 16.27 m (latitude 50.4°).

Yield of 1 kWp
1,134kWh/year
Tilt
37°1° east of south
10 kW
11,339kWh/year
Row pitch
16.27m · GCR 0.29
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,520 / 420Pa

Ground frame designer

A ground frame for a solar plant: Vyshenky

The designer opens with this place’s coordinates, latitude 50.4° for the row spacing and the DBN loads of the nearest regional centre — Черкаси, 127 km: snow 1,520 Pa, wind 420 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan59Feb97Mar118Apr139May143Jun146Jul143Aug113Sep80Oct36Nov24Dec

July: 146 kWh/kWp, December: 24 — 6.1 times less.

November: 36 against 39 in the oblast, 7.7% less.

Vyshenky: plants, kWh
kWpA yearJulyDecember
55,670730120
1011,3391,460240
1517,0092,190360

Snow and wind: Черкаси

Example: a 10 kW ground frame

For the loads of Cherkasy: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 49,705 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Myrhorodskyi RaionPoltava Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.