Solar plant: site data
Solar power plant in Shabelnyky, Poltavskyi Raion, Poltava Oblast
Shabelnyky: 1,170 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 2.4% above the oblast median (1,142). #26 of 751 in the rayon, #105 of 1856 in the oblast.
Poltava, the rayon centre, is 65 km away. 112 m above sea level. 9 km away: Kobelyaky, the nearest bigger centre, the same 1,164. Snow and wind from the nearest regional centre in the DBN — Полтава, 65 km. 11.28 m between rows, pitch 15.10 m (latitude 49.1°).
- Yield of 1 kWp
- 1,170kWh/year
- Tilt
- 37°1° east of south
- 10 kW
- 11,696kWh/year
- Row pitch
- 15.10m · GCR 0.32
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,450 / 470Pa
Ground frame designer
A ground frame for a solar plant: Shabelnyky
The designer opens with this place’s coordinates, latitude 49.1° for the row spacing and the DBN loads of the nearest regional centre — Полтава, 65 km: snow 1,450 Pa, wind 470 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 148 kWh/kWp, December: 28 — 5.3 times less.
December: 28 against 25 in the oblast, 12.0% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,848 | 740 | 140 |
| 10 | 11,696 | 1,480 | 280 |
| 15 | 17,544 | 2,220 | 420 |
Example: a 10 kW ground frame
For the loads of Poltava: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.
How these numbers are computed
Nearby
- Harbuzivka3 km1,170 kWh/kWp
- Perehonivka3 km1,170 kWh/kWp
- Lebedyne4 km1,165 kWh/kWp
- Sukhe4 km1,165 kWh/kWp
- Shenhury5 km1,165 kWh/kWp
- Sosnivka5 km1,169 kWh/kWp
All places: Poltavskyi RaionPoltava Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.