Solar plant: site data

Solar power plant in Lysivka, Myrhorodskyi Raion, Poltava Oblast

Lysivka: 1,134 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 0.7% below the oblast median (1,142). #189 of 430 in the rayon, #1359 of 1856 in the oblast.

Myrhorod, the rayon centre, is 34 km away. 105 m above sea level. 21 km away: Hadyach, the nearest bigger centre, 1,120 — 1.2% more here. Snow and wind from the nearest regional centre in the DBN — Полтава, 80 km. 12.26 m between rows, pitch 16.08 m (latitude 50.2°).

Yield of 1 kWp
1,134kWh/year
Tilt
37°2° east of south
10 kW
11,336kWh/year
Row pitch
16.08m · GCR 0.30
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,450 / 470Pa

Ground frame designer

A ground frame for a solar plant: Lysivka

The designer opens with this place’s coordinates, latitude 50.2° for the row spacing and the DBN loads of the nearest regional centre — Полтава, 80 km: snow 1,450 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan58Feb97Mar117Apr138May142Jun146Jul145Aug112Sep80Oct37Nov25Dec

July: 146 kWh/kWp, December: 25 — 5.8 times less.

January: 37 against 35 in the oblast, 5.7% more.

Lysivka: plants, kWh
kWpA yearJulyDecember
55,668730125
1011,3361,460250
1517,0042,190375

Snow and wind: Полтава

Example: a 10 kW ground frame

For the loads of Poltava: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Myrhorodskyi RaionPoltava Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.