Solar plant: site data

Solar power plant in Knyshivka, Kremenchutskyi Raion, Poltava Oblast

Knyshivka: 1,166 kWh per kWp a year, tilt 37° 2° east of south (PVGIS). 2.1% above the oblast median (1,142). #114 of 329 in the rayon, #152 of 1856 in the oblast.

Kremenchuk, the rayon centre, is 28 km away. 76 m above sea level. 28 km away: Kremenchuk, the nearest bigger centre, 1,174 — 0.7% less here. Snow and wind from the nearest regional centre in the DBN — Полтава, 77 km. 11.44 m between rows, pitch 15.26 m (latitude 49.3°).

Yield of 1 kWp
1,166kWh/year
Tilt
37°2° east of south
10 kW
11,662kWh/year
Row pitch
15.26m · GCR 0.31
T_min
-40 °Cregion I, north-western
Snow S₀ / wind W₀
1,450 / 470Pa

Ground frame designer

A ground frame for a solar plant: Knyshivka

The designer opens with this place’s coordinates, latitude 49.3° for the row spacing and the DBN loads of the nearest regional centre — Полтава, 77 km: snow 1,450 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan57Feb97Mar119Apr140May144Jun148Jul147Aug120Sep88Oct42Nov28Dec

July: 148 kWh/kWp, December: 28 — 5.3 times less.

December: 28 against 25 in the oblast, 12.0% more.

Knyshivka: plants, kWh
kWpA yearJulyDecember
55,831740140
1011,6621,480280
1517,4932,220420

Snow and wind: Полтава

Example: a 10 kW ground frame

For the loads of Poltava: 11.16 kWp, 18 panels, 389 kg of steel, 12 piles, materials ≈ 52,358 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Kremenchutskyi RaionPoltava Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.