Poland: solar plant site data
Solar power plant in Tychy, Poland: yield, tilt angle and row spacing
Tychy: 1,069 kWh per kWp a year at the optimal tilt of 39°, 2° east of south (PVGIS). Exactly the median of the main cities of Poland (1,065). #34 of 87 main cities of Poland by yield. For comparison, Kyiv: 1,114 kWh/kWp — 4.1% less here.
Tychy is in Silesian Voivodeship. Population 130,000 (GeoNames). 259 m above sea level. 14 km away: Katowice, the nearest bigger city, the same 1,065 kWh/kWp. 12.77 m between rows, pitch 16.49 m, GCR 0.29 (latitude 50.1°).
- Yield of 1 kWp
- 1,069kWh/year
- Tilt
- 39°2° east of south
- 10 kW
- 10,688kWh/year
- Row pitch
- 16.49m · GCR 0.29
- Rank in the country
- 34of 87 cities
Ground frame designer
A ground frame for a solar plant: Tychy
Latitude 50.1°: the tilt and the row pitch follow it. Enter the snow and wind for Poland in the designer, by the national annex to the Eurocode.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 129 kWh/kWp, December: 38 — 3.4 times less.
December: 38 against the median of 32 for the main cities of Poland, 18.8% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,344 | 645 | 190 |
| 10 | 10,688 | 1,290 | 380 |
| 15 | 16,032 | 1,935 | 570 |
Snow and wind loads
Snow and wind loads for a site in Poland follow PN-EN 1991-1-3 (snow) and PN-EN 1991-1-4 (wind) with the Polish National Annex (NA). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Poland: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.
The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.
Nearby cities
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation, population and divisions (changed)
- Where to take snow and wind loads from: PN-EN 1991-1-3 + NA, PN-EN 1991-1-4 + NA
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.