Poland: solar plant site data
Solar power plant in Tomaszów Mazowiecki, Poland: yield, tilt angle and row spacing
Tomaszów Mazowiecki: 1,059 kWh per kWp a year at the optimal tilt of 39°, 3° east of south (PVGIS). 0.6% below the median of the main cities of Poland (1,065). #53 of 87 main cities of Poland by yield. For comparison, Kyiv: 1,114 kWh/kWp — 4.9% less here.
Tomaszów Mazowiecki is in Łódź Voivodeship. Population 67,197 (GeoNames). 164 m above sea level. 25 km away: Piotrkow Trybunalski, the nearest bigger city, 1,069 kWh/kWp — 0.9% less here. 14.32 m between rows, pitch 18.04 m, GCR 0.27 (latitude 51.5°).
- Yield of 1 kWp
- 1,059kWh/year
- Tilt
- 39°3° east of south
- 10 kW
- 10,590kWh/year
- Row pitch
- 18.04m · GCR 0.27
- Rank in the country
- 53of 87 cities
Ground frame designer
A ground frame for a solar plant: Tomaszów Mazowiecki
Latitude 51.5°: the tilt and the row pitch follow it. Enter the snow and wind for Poland in the designer, by the national annex to the Eurocode.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
June: 130 kWh/kWp, December: 30 — 4.3 times less.
November: 37 against the median of 41 for the main cities of Poland, 9.8% less.
| kWp | A year | June | December |
|---|---|---|---|
| 5 | 5,295 | 650 | 150 |
| 10 | 10,590 | 1,300 | 300 |
| 15 | 15,885 | 1,950 | 450 |
Snow and wind loads
Snow and wind loads for a site in Poland follow PN-EN 1991-1-3 (snow) and PN-EN 1991-1-4 (wind) with the Polish National Annex (NA). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Poland: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.
The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.
Nearby cities
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation, population and divisions (changed)
- Where to take snow and wind loads from: PN-EN 1991-1-3 + NA, PN-EN 1991-1-4 + NA
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.