Poland: solar plant site data
Solar power plant in Tarnobrzeg, Poland: yield, tilt angle and row spacing
Tarnobrzeg: 1,096 kWh per kWp a year at the optimal tilt of 39°, 2° east of south (PVGIS). 2.9% above the median of the main cities of Poland (1,065). #4 of 87 main cities of Poland by yield. For comparison, Kyiv: 1,114 kWh/kWp — 1.6% less here.
Tarnobrzeg is in Subcarpathian Voivodeship. Population 50,459 (GeoNames). 162 m above sea level. 26 km away: Stalowa Wola, the nearest bigger city, 1,065 kWh/kWp — 2.9% more here. 13.22 m between rows, pitch 16.94 m, GCR 0.28 (latitude 50.6°).
- Yield of 1 kWp
- 1,096kWh/year
- Tilt
- 39°2° east of south
- 10 kW
- 10,958kWh/year
- Row pitch
- 16.94m · GCR 0.28
- Rank in the country
- 4of 87 cities
Ground frame designer
A ground frame for a solar plant: Tarnobrzeg
Latitude 50.6°: the tilt and the row pitch follow it. Enter the snow and wind for Poland in the designer, by the national annex to the Eurocode.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 132 kWh/kWp, December: 35 — 3.8 times less.
November: 45 against the median of 41 for the main cities of Poland, 9.8% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,479 | 660 | 175 |
| 10 | 10,958 | 1,320 | 350 |
| 15 | 16,437 | 1,980 | 525 |
Snow and wind loads
Snow and wind loads for a site in Poland follow PN-EN 1991-1-3 (snow) and PN-EN 1991-1-4 (wind) with the Polish National Annex (NA). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Poland: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.
The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.
Nearby cities
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation, population and divisions (changed)
- Where to take snow and wind loads from: PN-EN 1991-1-3 + NA, PN-EN 1991-1-4 + NA
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.