Poland: solar plant site data
Solar power plant in Kędzierzyn-Koźle, Poland: yield, tilt angle and row spacing
Kędzierzyn-Koźle: 1,080 kWh per kWp a year at the optimal tilt of 39°, 2° east of south (PVGIS). 1.4% above the median of the main cities of Poland (1,065). #21 of 87 main cities of Poland by yield. For comparison, Kyiv: 1,114 kWh/kWp — 3.1% less here.
Kędzierzyn-Koźle is in Opole Voivodeship. Population 65,636 (GeoNames). 182 m above sea level. 33 km away: Gliwice, the nearest bigger city, the same 1,082 kWh/kWp. 12.99 m between rows, pitch 16.71 m, GCR 0.29 (latitude 50.3°).
- Yield of 1 kWp
- 1,080kWh/year
- Tilt
- 39°2° east of south
- 10 kW
- 10,795kWh/year
- Row pitch
- 16.71m · GCR 0.29
- Rank in the country
- 21of 87 cities
Ground frame designer
A ground frame for a solar plant: Kędzierzyn-Koźle
Latitude 50.3°: the tilt and the row pitch follow it. Enter the snow and wind for Poland in the designer, by the national annex to the Eurocode.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 129 kWh/kWp, December: 36 — 3.6 times less.
December: 36 against the median of 32 for the main cities of Poland, 12.5% more.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,398 | 645 | 180 |
| 10 | 10,795 | 1,290 | 360 |
| 15 | 16,193 | 1,935 | 540 |
Snow and wind loads
Snow and wind loads for a site in Poland follow PN-EN 1991-1-3 (snow) and PN-EN 1991-1-4 (wind) with the Polish National Annex (NA). Solispec computes loads by the Ukrainian DBN V.1.2-2 only, so this page shows no snow or wind values for Poland: enter the characteristic values from these documents in the designer’s «Own snow S0» and «Own wind W0» fields.
The frame calculation for such a site is preliminary: before installation it must be checked by an engineer who works to the country’s standards.
Nearby cities
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation, population and divisions (changed)
- Where to take snow and wind loads from: PN-EN 1991-1-3 + NA, PN-EN 1991-1-4 + NA
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.