Solar plant: site data
Solar power plant in Volodymyrivka, Bashtanskyi Raion, Mykolaiv Oblast
Volodymyrivka: 1,193 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). Exactly the oblast median (1,198). #184 of 279 in the rayon, #524 of 909 in the oblast.
Novyi Buh, the rayon centre, is 13 km away. 38 m above sea level. 13 km away: Novyi Buh, the nearest bigger centre, 1,181 — 1.0% more here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 82 km. 9.98 m between rows, pitch 13.85 m (latitude 47.7°).
- Yield of 1 kWp
- 1,193kWh/year
- Tilt
- 36°3° east of south
- 10 kW
- 11,928kWh/year
- Row pitch
- 13.85m · GCR 0.35
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 870 / 470Pa
Ground frame designer
A ground frame for a solar plant: Volodymyrivka
The designer opens with this place’s coordinates, latitude 47.7° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 82 km: snow 870 Pa, wind 470 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 154 kWh/kWp, December: 32 — 4.8 times less.
January: 36 against 38 in the oblast, 5.3% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,964 | 770 | 160 |
| 10 | 11,928 | 1,540 | 320 |
| 15 | 17,892 | 2,310 | 480 |
Example: a 10 kW ground frame
For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.
How these numbers are computed
Nearby
- Shchaslyve1 km1,193 kWh/kWp
- Volodymyro-Pavlivka2 km1,193 kWh/kWp
- Sofiyivka3 km1,187 kWh/kWp
- Vivsyanivka3 km1,188 kWh/kWp
- Ulyanivka3 km1,195 kWh/kWp
- Veselyi Podil6 km1,190 kWh/kWp
All places: Bashtanskyi RaionMykolaiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.