Solar plant: site data

Solar power plant in Rozanivka, Bashtanskyi Raion, Mykolaiv Oblast

Rozanivka: 1,182 kWh per kWp a year, tilt 36° 4° east of south (PVGIS). 1.3% below the oblast median (1,198). #235 of 279 in the rayon, #673 of 909 in the oblast.

Novyi Buh, the rayon centre, is 15 km away. 71 m above sea level. 15 km away: Novyi Buh, the nearest bigger centre, the same 1,181. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 81 km. 10.06 m between rows, pitch 13.93 m (latitude 47.8°).

Yield of 1 kWp
1,182kWh/year
Tilt
36°4° east of south
10 kW
11,819kWh/year
Row pitch
13.93m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,230 / 410Pa

Ground frame designer

A ground frame for a solar plant: Rozanivka

The designer opens with this place’s coordinates, latitude 47.8° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 81 km: snow 1,230 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

36Jan53Feb96Mar123Apr138May141Jun153Jul149Aug124Sep94Oct46Nov30Dec

July: 153 kWh/kWp, December: 30 — 5.1 times less.

December: 30 against 33 in the oblast, 9.1% less.

Rozanivka: plants, kWh
kWpA yearJulyDecember
55,910765150
1011,8191,530300
1517,7292,295450

Snow and wind: Кропивницький

Example: a 10 kW ground frame

For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 48,082 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Bashtanskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.