Solar plant: site data

Solar power plant in Novovasylivka, Bashtanskyi Raion, Mykolaiv Oblast

Novovasylivka: 1,172 kWh per kWp a year, tilt 36° 4° east of south (PVGIS). 2.2% below the oblast median (1,198). #265 of 279 in the rayon, #821 of 909 in the oblast.

Novyi Buh, the rayon centre, is 33 km away. 117 m above sea level. 14 km away: Kazanka, the nearest bigger centre, 1,179 — 0.6% less here. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 73 km. 10.17 m between rows, pitch 14.04 m (latitude 47.9°).

Yield of 1 kWp
1,172kWh/year
Tilt
36°4° east of south
10 kW
11,718kWh/year
Row pitch
14.04m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,230 / 410Pa

Ground frame designer

A ground frame for a solar plant: Novovasylivka

The designer opens with this place’s coordinates, latitude 47.9° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 73 km: snow 1,230 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

35Jan52Feb93Mar121Apr138May142Jun152Jul149Aug123Sep93Oct44Nov29Dec

July: 152 kWh/kWp, December: 29 — 5.2 times less.

December: 29 against 33 in the oblast, 12.1% less.

Novovasylivka: plants, kWh
kWpA yearJulyDecember
55,859760145
1011,7181,520290
1517,5772,280435

Snow and wind: Кропивницький

Example: a 10 kW ground frame

For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 48,082 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Bashtanskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.