Solar plant: site data

Solar power plant in Novoyurivka, Mykolaivskyi Raion, Mykolaiv Oblast

Novoyurivka: 1,219 kWh per kWp a year, tilt 36° 5° east of south (PVGIS). 1.8% above the oblast median (1,198). #205 of 238 in the rayon, #271 of 909 in the oblast.

Mykolayiv, the rayon centre, is 32 km away. 50 m above sea level. 12 km away: Nova Odesa, the nearest bigger centre, 1,212 — 0.6% more here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 32 km. 9.68 m between rows, pitch 13.55 m (latitude 47.2°).

Yield of 1 kWp
1,219kWh/year
Tilt
36°5° east of south
10 kW
12,192kWh/year
Row pitch
13.55m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
870 / 470Pa

Ground frame designer

A ground frame for a solar plant: Novoyurivka

The designer opens with this place’s coordinates, latitude 47.2° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 32 km: snow 870 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

40Jan57Feb104Mar126Apr141May142Jun153Jul150Aug126Sep97Oct49Nov34Dec

July: 153 kWh/kWp, December: 34 — 4.5 times less.

February: 57 against 54 in the oblast, 5.6% more.

Novoyurivka: plants, kWh
kWpA yearJulyDecember
56,096765170
1012,1921,530340
1518,2882,295510

Snow and wind: Миколаїв

Example: a 10 kW ground frame

For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.