Solar plant: site data

Solar power plant in Maryivka, Voznesenskyi Raion, Mykolaiv Oblast

Maryivka: 1,184 kWh per kWp a year, tilt 37° facing south (PVGIS). 1.2% below the oblast median (1,198). #177 of 252 in the rayon, #651 of 909 in the oblast.

Voznesensk, the rayon centre, is 35 km away. 52 m above sea level. 30 km away: Pervomaysk, the nearest bigger centre, 1,169 — 1.2% more here. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 114 km. 10.34 m between rows, pitch 14.16 m (latitude 47.8°).

Yield of 1 kWp
1,184kWh/year
Tilt
37°facing south
10 kW
11,835kWh/year
Row pitch
14.16m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,230 / 410Pa

Ground frame designer

A ground frame for a solar plant: Maryivka

The designer opens with this place’s coordinates, latitude 47.8° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 114 km: snow 1,230 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

40Jan54Feb100Mar123Apr138May140Jun149Jul146Aug122Sep94Oct45Nov33Dec

July: 149 kWh/kWp, December: 33 — 4.5 times less.

November: 45 against 48 in the oblast, 6.3% less.

Maryivka: plants, kWh
kWpA yearJulyDecember
55,918745165
1011,8351,490330
1517,7532,235495

Snow and wind: Кропивницький

Example: a 10 kW ground frame

For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 48,082 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Voznesenskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.