Solar plant: site data

Solar power plant in Lymany, Mykolaivskyi Raion, Mykolaiv Oblast

Lymany: 1,288 kWh per kWp a year, tilt 37° 1° east of south (PVGIS). 7.5% above the oblast median (1,198). #18 of 238 in the rayon, #18 of 909 in the oblast.

Mykolayiv, the rayon centre, is 27 km away. 12 m above sea level. 27 km away: Mykolayiv, the nearest bigger centre, 1,253 — 2.8% more here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 27 km. 9.62 m between rows, pitch 13.44 m (latitude 46.7°).

Yield of 1 kWp
1,288kWh/year
Tilt
37°1° east of south
10 kW
12,882kWh/year
Row pitch
13.44m · GCR 0.36
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
870 / 470Pa

Ground frame designer

A ground frame for a solar plant: Lymany

The designer opens with this place’s coordinates, latitude 46.7° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 27 km: snow 870 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

47Jan64Feb111Mar133Apr147May145Jun156Jul155Aug132Sep103Oct56Nov39Dec

July: 156 kWh/kWp, December: 39 — 4.0 times less.

January: 47 against 38 in the oblast, 23.7% more.

Lymany: plants, kWh
kWpA yearJulyDecember
56,441780195
1012,8821,560390
1519,3232,340585

Snow and wind: Миколаїв

Example: a 10 kW ground frame

For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.