Solar plant: site data

Solar power plant in Kapustyne, Mykolaivskyi Raion, Mykolaiv Oblast

Kapustyne: 1,247 kWh per kWp a year, tilt 37° 3° east of south (PVGIS). 4.1% above the oblast median (1,198). #89 of 238 in the rayon, #92 of 909 in the oblast.

Mykolayiv, the rayon centre, is 10 km away. 21 m above sea level. 10 km away: Mykolayiv, the nearest bigger centre, 1,253 — 0.5% less here. Snow and wind from the nearest regional centre in the DBN — Миколаїв, 11 km. 9.83 m between rows, pitch 13.65 m (latitude 47.1°).

Yield of 1 kWp
1,247kWh/year
Tilt
37°3° east of south
10 kW
12,467kWh/year
Row pitch
13.65m · GCR 0.35
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
870 / 470Pa

Ground frame designer

A ground frame for a solar plant: Kapustyne

The designer opens with this place’s coordinates, latitude 47.1° for the row spacing and the DBN loads of the nearest regional centre — Миколаїв, 11 km: snow 870 Pa, wind 470 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

44Jan62Feb106Mar128Apr143May142Jun153Jul151Aug128Sep100Oct52Nov38Dec

July: 153 kWh/kWp, December: 38 — 4.0 times less.

January: 44 against 38 in the oblast, 15.8% more.

Kapustyne: plants, kWh
kWpA yearJulyDecember
56,234765190
1012,4671,530380
1518,7012,295570

Snow and wind: Миколаїв

Example: a 10 kW ground frame

For the loads of Mykolaiv: 11.16 kWp, 18 panels, 372 kg of steel, 14 piles, materials ≈ 50,842 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Mykolaivskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.