Solar plant: site data
Solar power plant in Hannivka, Voznesenskyi Raion, Mykolaiv Oblast
Hannivka: 1,165 kWh per kWp a year, tilt 36° 3° east of south (PVGIS). 2.7% below the oblast median (1,198). #250 of 252 in the rayon, #876 of 909 in the oblast.
Voznesensk, the rayon centre, is 61 km away. 192 m above sea level. 28 km away: Novoukrayinka, the nearest bigger centre, 1,152 — 1.1% more here. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 67 km. 10.26 m between rows, pitch 14.13 m (latitude 48.1°).
- Yield of 1 kWp
- 1,165kWh/year
- Tilt
- 36°3° east of south
- 10 kW
- 11,650kWh/year
- Row pitch
- 14.13m · GCR 0.34
- T_min
- -42 °Cregion II, south-eastern
- Snow S₀ / wind W₀
- 1,230 / 410Pa
Ground frame designer
A ground frame for a solar plant: Hannivka
The designer opens with this place’s coordinates, latitude 48.1° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 67 km: snow 1,230 Pa, wind 410 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
July: 151 kWh/kWp, December: 30 — 5.0 times less.
November: 43 against 48 in the oblast, 10.4% less.
| kWp | A year | July | December |
|---|---|---|---|
| 5 | 5,825 | 755 | 150 |
| 10 | 11,650 | 1,510 | 300 |
| 15 | 17,475 | 2,265 | 450 |
Example: a 10 kW ground frame
For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 48,082 UAH.
How these numbers are computed
Nearby
- Darnytsya1 km1,167 kWh/kWp
- Yelyzavetivka3 km1,167 kWh/kWp
- Mostove5 km1,165 kWh/kWp
- Novofedorivka5 km1,166 kWh/kWp
- Kostyvate6 km1,165 kWh/kWp
- Voronyne6 km1,176 kWh/kWp
All places: Voznesenskyi RaionMykolaiv Oblast: rayons and towns
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.