Solar plant: site data

Solar power plant in Bratske, Voznesenskyi Raion, Mykolaiv Oblast

Bratske: 1,183 kWh per kWp a year, tilt 36° 4° east of south (PVGIS). 1.3% below the oblast median (1,198). #182 of 252 in the rayon, #661 of 909 in the oblast.

Voznesensk, the rayon centre, is 38 km away. 86 m above sea level. 38 km away: Voznesensk, the nearest bigger centre, 1,192 — 0.8% less here. Snow and wind from the nearest regional centre in the DBN — Кропивницький, 88 km. 10.12 m between rows, pitch 13.99 m (latitude 47.9°).

Yield of 1 kWp
1,183kWh/year
Tilt
36°4° east of south
10 kW
11,829kWh/year
Row pitch
13.99m · GCR 0.34
T_min
-42 °Cregion II, south-eastern
Snow S₀ / wind W₀
1,230 / 410Pa

Ground frame designer

A ground frame for a solar plant: Bratske

The designer opens with this place’s coordinates, latitude 47.9° for the row spacing and the DBN loads of the nearest regional centre — Кропивницький, 88 km: snow 1,230 Pa, wind 410 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

37Jan53Feb98Mar123Apr139May140Jun151Jul148Aug122Sep94Oct46Nov32Dec

July: 151 kWh/kWp, December: 32 — 4.7 times less.

November: 46 against 48 in the oblast, 4.2% less.

Bratske: plants, kWh
kWpA yearJulyDecember
55,915755160
1011,8291,510320
1517,7442,265480

Snow and wind: Кропивницький

Example: a 10 kW ground frame

For the loads of Kropyvnytskyi: 11.16 kWp, 18 panels, 372 kg of steel, 12 piles, materials ≈ 48,082 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Voznesenskyi RaionMykolaiv Oblast: rayons and towns

Free calculators

Sources