Solar plant: site data

Solar power plant in Tukholka, Stryiskyi Raion, Lviv Oblast

Tukholka: 1,033 kWh per kWp a year, tilt 37° 3° east of south (PVGIS). 4.7% below the oblast median (1,084). #253 of 286 in the rayon, #1454 of 1532 in the oblast.

Stryi, the rayon centre, is 60 km away. 735 m above sea level — above 500 m the DBN snow and wind are higher. 56 km away: Drohobych, the nearest bigger centre, 1,073 — 3.7% less here. Snow and wind from the nearest regional centre in the DBN — Ужгород, 77 km. 11.11 m between rows, pitch 14.93 m (latitude 48.9°).

Yield of 1 kWp
1,033kWh/year
Tilt
37°3° east of south
10 kW
10,332kWh/year
Row pitch
14.93m · GCR 0.32
T_min
-38 °Cregion IIIA, Carpathian
Snow S₀ / wind W₀
1,340 / 370Pa

Ground frame designer

A ground frame for a solar plant: Tukholka

The designer opens with this place’s coordinates, latitude 48.9° for the row spacing and the DBN loads of the nearest regional centre — Ужгород, 77 km: snow 1,340 Pa, wind 370 Pa.

  • No sign-up
  • Snow and wind check
  • Drawings and estimate

Yield by month

41Jan59Feb90Mar106Apr113May117Jun125Jul125Aug102Sep80Oct46Nov30Dec

July: 125 kWh/kWp, December: 30 — 4.2 times less.

May: 113 against 124 in the oblast, 8.9% less.

Tukholka: plants, kWh
kWpA yearJulyDecember
55,166625150
1010,3321,250300
1515,4981,875450

Snow and wind: Ужгород

Example: a 10 kW ground frame

For the loads of Uzhhorod: 11.16 kWp, 18 panels, 366 kg of steel, 12 piles, materials ≈ 48,597 UAH.

The whole frame: drawing, BOM, checks

How these numbers are computed

Nearby

All places: Stryiskyi RaionLviv Oblast: rayons and towns

Free calculators

Sources

Preliminary calculation: a design needs an engineer’s check.