Solar plant: site data
Solar power plant in Nyzhnia Rozhanka, Stryiskyi Raion, Lviv Oblast
Nyzhnia Rozhanka: 996 kWh per kWp a year, tilt 36° 9° east of south (PVGIS). 8.1% below the oblast median (1,084). #275 of 286 in the rayon, #1512 of 1532 in the oblast.
Stryi, the rayon centre, is 55 km away. 645 m above sea level — above 500 m the DBN snow and wind are higher. 55 km away: Stryi, the nearest bigger centre, 1,085 — 8.2% less here. Snow and wind from the nearest regional centre in the DBN — Івано-Франківськ, 88 km. 10.81 m between rows, pitch 14.68 m (latitude 48.8°).
- Yield of 1 kWp
- 996kWh/year
- Tilt
- 36°9° east of south
- 10 kW
- 9,958kWh/year
- Row pitch
- 14.68m · GCR 0.33
- T_min
- -38 °Cregion IIIA, Carpathian
- Snow S₀ / wind W₀
- 1,410 / 500Pa
Ground frame designer
A ground frame for a solar plant: Nyzhnia Rozhanka
The designer opens with this place’s coordinates, latitude 48.8° for the row spacing and the DBN loads of the nearest regional centre — Івано-Франківськ, 88 km: snow 1,410 Pa, wind 500 Pa.
- No sign-up
- Snow and wind check
- Drawings and estimate
Yield by month
August: 123 kWh/kWp, December: 28 — 4.4 times less.
December: 28 against 32 in the oblast, 12.5% less.
| kWp | A year | August | December |
|---|---|---|---|
| 5 | 4,979 | 615 | 140 |
| 10 | 9,958 | 1,230 | 280 |
| 15 | 14,937 | 1,845 | 420 |
Snow and wind: Івано-Франківськ
Example: a 10 kW ground frame
For the loads of Ivano-Frankivsk: 11.16 kWp, 18 panels, 410 kg of steel, 16 piles, materials ≈ 54,212 UAH.
How these numbers are computed
Nearby
Free calculators
Sources
- PVGIS © European Union, 2001–2026 — yield, tilt and azimuth, data as of 2026-10-10
- GeoNames (CC BY 4.0) — coordinates, elevation and divisions (changed)
- DBN V.1.2-2:2006, DSTU-N B V.1.1-27:2010
- How these numbers are computed
Preliminary calculation: a design needs an engineer’s check.